Posts Tagged ‘FBI’

Chicago-Extreme Fire Behavior

Saturday, March 6th, 2010

Updated March 7, 2010 with Longer Video Clip of this Incident

On the afternoon of February 18, 2010, firefighters in Chicago responded to a residential fire at 4855 S. Paulina Street. First arriving companies discovered a fire in the basement of a 1-1/2 story, wood frame, single family dwelling and initiated fire attack and horizontal ventilation of the floors above the fire.

Based on news accounts, the company assigned to fire attack was in the stairwell and another firefighter was performing horizontal ventilation of the floors above the fire on Side C when a backdraft or smoke explosion occurred. Three firefighters on the interior and the firefighter on the ladder on Side C were injured and were transported to local hospitals for burns and possible airway injuries.

Figure 1. Consider Key Fire Behavior Indicators

chicago_backdraft

B-SAHF Indicators

Recognizing subtle fire behavior indicators during incident operations can be difficult and important indicators are often only visible from one location (other than where you are). What Building, Smoke, Heat, and Flame (B-SAHF) indicators would you anticipate seeing if potential backdraft conditions exist (or may develop as the incident progresses)? How would this differ from the indicators that conditions may present risk of a smoke explosion?

For more information on key fire behavior indicators related to ventilation controlled burning regime, decay stage fires, backdraft, and smoke explosion, see the following posts:

Incident Video

A video of the incident at 4855 S. Paulina Street was recently posted on YouTube (a shorter version is posted on Firevideo.net). It appears that the video may have been shot through a window by an occupant of the D2 exposure. The title of this video is “Chicago Smoke Explosion”. After watching the video and answering the questions posed in this post, do you think that this was a backdraft or smoke explosion? Why?

One of the great assets of using video as a learning tool is the ability to stop the action and go back to review key information. Watch the video and stop the action as necessary to answer the following questions”

  • Pause at 02:05. What B-SAHF indicators could be observed on Side C up to this point in the video clip?
  • Pause at 02:49. What indicators could be observed while the firefighter was forcing entry and ventilating the daylight basement on Side C?
  • Pause at 03:13. What B-SAHF indicators can be observed at the door on Side C prior to forced entry?
  • Pause at 03:35. What indicators can be observed at the door after forcing the outer door (prior to ventilation of the window on Floor 2)?
  • Pause at 03:44. What B-SHAF indicators do you observe at the window on Floor 2 prior to breaking the glass?
  • Pause at 03:55. What indicators are observed at the window on Floor 2 immediately after breaking the glass?
  • Pause at 04:08. What B-SAHF indicators were present after the ventilation of the window on Floor 2 Side C was completed and 04:08 in the video clip?

After answering the questions, watch the complete clip. Do you think that this was a backdraft or smoke explosion? If you thought that this was a backdraft: Did you see potential indicators? If so what were they? If not, why do you think that this was the case? If you think that this was a smoke explosion, what indications lead you to this conclusion? What indicators were present?

You may want to watch this video clip several times and give some thought to what factors were influencing the B-SAHF indicators (particularly smoke, air track, and heat). Were these indicators consistent with your perception of backdraft indicators? Is so, how? If not, what was different? What indicators may have been visible from other vantage points. Remember that the video provides a view from a single perspective (and one that is considerably different than the crews working at this incident).

The next post in this series will take a closer look at the video and key fire behavior indicators.

Ed Hartin, MS, EFO, MIFireE, CFO

Battle Drill Part 3

Sunday, February 21st, 2010

A Quick Review

As discussed in the previous posts in this series, military battle drills are an immediate response to enemy contact that requires fire and maneuver in order to succeed. Battle drills are initiated with minimal commands from the unit leader. Soldiers or marines execute preplanned, sequential actions in response to enemy contact (see Figure 1).

Figure 1. Battle Drill

battle_drill

Battle Drill Part 2 addressed the appropriate reaction of a team of firefighters on a primary hoseline when confronted with rapidly worsening fire conditions that are not readily controllable once they occur (e.g., flashover, wind driven fire conditions). As when a military unit is ambushed, the fire and maneuver of battle drill involves more than one weapon. This post will address the role and reaction of backup lines in the extreme fire behavior battle drill.

Backup Lines

Once a hoseline has been deployed for fire attack it is good practice to stretch a backup line. Klaene and Sanders (2008) observe that backup lines are needed to protect the crew on the initial attack line and to provide additional flow if needed (p. 216). Unfortunately, many firefighters see the backup line as simply another attack line and miss the first and primary function of this hoseline to protect crews on primary hoselines.

The first priority in fire attack operations is to get a hoseline in position to apply water effectively to the fire. To this end, hoselines are deployed in series (attack line first, then backup line) not in parallel, where both lines are attempting to advance and maneuver in the same space. The crew of the backup line can often assist in pulling up additional hose for the attack line (particularly when crews are lightly staffed). As illustrated in Figure 2, the backup line is positioned to protect the means of egress and if necessary support fire attack.

Figure 2. Attack and Backup Line Placement

simple_floor_plan

Extreme Fire Behavior Battle Drill

As discussed in Battle Drill Part 2, the thermal insult experienced in an extreme fire behavior event is dependent on temperature (of gases and compartment linings) and flow of hot gases. The higher the temperature and faster the speed of gas flow, the higher the heat flux. Survival requires that crews on hoselines extinguish or block the flames, cool hot gases, and maneuver out of the flow path to a point of egress or area of safer refuge.

Crews engaged in fire attack or search are often first to encounter rapidly deteriorating fire conditions. Hose Handling and Nozzle Technique Drill 8 outlined the immediate actions that should be taken to support a tactical withdrawal under severe fire conditions. In these circumstances, the crew staffing the backup line has a critical role in supporting withdrawing crews.

Fire conditions that are beyond the capability of a single hoseline may be controlled by the higher flow rate from multiple lines. As noted by Klaene and Sanders (2008) one of the functions of backup lines is to provide additional flow if needed (p. 216). The attack line and backup line operating in a coordinated manner may be able to control fire conditions and allow continuation of fire attack. If this is the case, these lines should be reinforced by deployment of one or more additional backup lines.

If fire conditions cannot be controlled, and the attack line must be withdrawn while maintaining water application to protect the crew, the crew on the backup line can aid in withdrawal of attack and/or search hoselines. If the hoseline is not withdrawn as the firefighter on the nozzle retreats, the hose may kink or become exposed to flames (either of which may result in loss of water supply to the nozzle).

While the attack or search crew is likely to be first to encounter worsening fire conditions, this is not always the case. Depending on fire location and building configuration, fire spread may cut off the attack or search line from behind. In this situation, the backup line becomes the primary means of defense for operating crews.

Regardless of how deteriorating conditions develop, safe and effective tactical withdrawal requires a coordinated effort between interior crews and as soon as possible, report of conditions to Command and if necessary transmit a Mayday message.

Drill 9-Extreme Fire Behavior Battle Drill-The Backup Line: Key hose handling and nozzle techniques when faced with extreme fire behavior are the ability to apply long pulses of water fog or maintaining a continuous flow rate while maneuvering backwards. However, the backup line may initially need to advance to support fire attack, and then if necessary cover and support other crews as they withdraw.

Hose Handling & Nozzle Technique Drill 9 Instructional Plan

Skill in operation and maneuver of a single hoseline is a foundational firefighting skill. However, in the extreme fire behavior battle drill, coordinated operation of the attack and backup line is essential, making Hose Handling & Nozzle Technique Drill 9 an important step in skill development.

References

Klaene, B. & Sanders, R. (2008) Structural Firefighting Strategy and Tactics (2nd ed.). Sudbury, MA: Jones & Bartlett.

Battle Drill Part 2

Thursday, February 11th, 2010

A Quick Review

As discussed in the last post in this series, military battle drills are an immediate response to enemy contact that requires fire and maneuver in order to succeed. Battle drills are initiated with minimal commands from the unit leader. Soldiers or marines execute preplanned, sequential actions in response to enemy contact.

This post discusses application of the battle drill concept in training firefighters to react appropriately on contact with our enemy (the fire) which requires fire (application of water) and maneuver (movement to a safer location) in order to succeed.

Remember: The key elements of a battle drill are fire and maneuver! This requires the ability to operate and maintain control of the hoseline while moving backward.

Working Without a Hoseline

In the United States, it is common for some companies working on the fireground to operate inside burning buildings without a hoseline (particularly when performing search). While common, this practice places firefighters at considerable risk when faced with extreme fire behavior. Without a hoseline your only defense against rapid fire progress is recognition of developing conditions and immediate reaction to escape to a safer location (see video below); which is not always possible. In some cases, firefighters fail to recognize developing conditions or the speed with which conditions will change. In other cases, firefighters are unable to escape or take refuge outside the flow path of hot gases and flames quickly enough.

Cl

If your department’s operational doctrine includes companies working on the interior without a hoseline (or without being directly supported by a hoseline), it is essential that firefighters are trained to 1) recognize early indicators of potential for extreme fire behavior and 2) maintain a high level of awareness regarding locations which may provide an area of refuge. When confronted by rapidly worsening conditions, action to escape must be immediate and without hesitation.

Extreme Fire Behavior Battle Drill

Regardless of their assignment (e.g., fire attack, primary search), firefighters with a hoseline have a solid means of maintaining orientation, a defined primary escape route, and the ability to actively control the fire environment through application of water. However, as always, safe and effective operation in the fire environment is dependent on a solid size-up, dynamic risk assessment, maintenance of a high level of situational awareness, and proactively controlling the fire environment. The best way to deal with extreme fire behavior is to avoid it or prevent it from occurring. For more information on reading the fire and key fire behavior indicators related to potential for extreme fire behavior, see:

In situations where you were unable to recognize potential for extreme fire behavior or you have been unable to control the fire environment, immediate action is required!

This is my nozzle, there are many like it but this one is mine. My nozzle is my best friend. It is my life. I must master it as I master my life. Without me it is useless, without my nozzle I am useless.

I will use my nozzle effectively and efficiently to put water where it is needed. I will learn its weaknesses, its strengths, its parts, and its care. I will guard it against damage, keep it clean and ready. This I swear.

As stated in the first paragraph of this adaptation of the United States Marine Corps Riflemans’ Creed, Without my nozzle I am useless.

The extent of thermal insult experienced in an extreme fire behavior event is dependent on both radiant and convective heat flux. Total radiant heat flux is dependent on temperature (of gases and compartment linings) and flow of hot gases. The higher the temperature and faster the speed of gas flow, the higher the heat flux. These scientific concepts drive the key elements of the extreme fire behavior battle drill. Extinguish or block the flames, cool hot gases, and maneuver out of the flow path to a point of egress or area of safer refuge.

Drill 8-Extreme Fire Behavior Battle Drill: Key hose handling and nozzle techniques when faced with extreme fire behavior are the ability to apply long pulses of water fog or maintaining a continuous flow rate while maneuvering backwards. This requires a coordinated effort on the part of the nozzle operator, backup firefighter, and potentially other firefighters working on the hoseline or at the point of entry.

Hose Handling & Nozzle Technique Drill 8 Instructional Plan

While this drill focuses on single company operations, it is important to extend this training to include crews operating backup lines. The importance, function, and operation of the backup line will be the focus of the next post in this series.

Not all That is Learned is Taught

When training to operate in a hazardous environment, avoid the mindset that it’s only a drill. As often observed, you will play the way that you practice. Extreme stress can activate inappropriate routine responses. For example, a Swedish army officer suddenly stood up while his unit was under fire while engaged in peacekeeping efforts in Bosnia. When asked about this response, he explained that in training, he often stood up while leading exercises (Wallenius, Johansson, & Larsson, 2002).

“A simple set of skills , combined with an emphasis on actions requiring complex and gross motor muscle operations (as opposed to fine motor control), all extensively rehearsed, allows for extraordinary performance levels under stress” (Grossman, 2008, p. 38).

When developing skill in nozzle technique and hose handline, and in particular the critical skills required to effectively perform this extreme fire behavior battle drill, it is essential to maintain critical elements of context such as appropriate use of personal protective equipment, position, and technique.

Ed Hartin, MS, EFO, MIFireE, CFO

References

Grossman, D. (2008). On-combat: The psychology and physiology of deadly conflict in war and peace. Millstadt, IL: Warrior Science Publications.

Wallenius, C. Johansson, C. & Larsson, G. (2002). Reactions and performance of Swedish peacekeepers in life-threatening situations. International Peacekeeping, 9(1), 133-152.

2010 Congreso Internacional Fuego y Rescate

Saturday, January 30th, 2010

At a formal dinner on 23 January 2010, Chief Ed Hartin was recognized as an honorary member of Company 1 “Germania” of the Valdivia, Chile Fire Department. In addition, he was awarded a commendation for supporting the ongoing professional development of the members of Company 1 “Germania” of the Valdivia, Chile Fire Department and encouraging them in their efforts to share their knowledge with Chile’s fire service.

Commendation for Support of Company 1 “Germania”

commendation

Left to Right: Teniente Juan Esteban Kunstmann, Chief Ed Hartin, Capitán Francisco Silva V.

On 24-27 January 2007, the Company 1 “Germania” of the Valdivia, Chile Fire Department hosted the first international fire service congress to be held in South America. Participants included over 150 firefighters and officers from Chile, Peru, Argentina, and the United States. The congress provided an opportunity to participate in both classroom and hands-on workshops on a wide range of fire service topics including fire behavior, ventilation, search, rapid intervention, technical rescue, and extrication. While topical areas were diverse, the congress had a substantive emphasis on compartment fire behavior with lectures presented by CFBT-US Chief Instructor Ed Hartin and Geraldo Crespo of Contraincendio in Buenos Aires, Argentina and practical training sessions conducted by Ed Hartin and Juan Esteban Kunstmann of the Valdivia Company 1 “Germania”.

Lecture Presentation

ed_cl_classroom

Lecture presentations by CFBT-US Chief Instructor Ed Hartin included (click on the links for a copies of the presentations):

CFBT practical skills sessions were held at the Valdivia Fire Department’s training center and focused on developing basic skill in nozzle technique and understanding fire development in a compartment.

This is My Nozzle! There are many like it, but this one is mine…

ed_cl_practical

Center: Ed Hartin

Practicing Nozzle Techniques

juan_cl_practical

Right: Teniente Juan Esteban Kunstmann

International Collaboration

giancarlo_cl_practical

Left to Right: Battalion Chief Danny Sheridan, FDNY and Capitán Giancarlo Passalacqua Cognoro, Lima, Pe?u Cuerpo General de Bomberos Voluntarios

Congratulations to the members of Company 1 “Germania” for their success with the first Congreso Internacional Fuego y Rescate! I look forward to working with these outstanding fire service professionals in their ongoing efforts to learn and share knowledge with the fire service throughout Chile, Latin America, and the World.

Ed Hartin, MS, EFO, MIFireE, CFO

Recent Extreme Fire Behavior

Tuesday, January 19th, 2010

Two recent events in Baltimore, Maryland and Gary, Indiana point to the criticality of recognizing key fire behavior indicators and understanding practical fire dynamics.

Five Firefighters Injured in Baltimore

Early on the morning of Friday, January 15, 2010, the Baltimore City Fire Department was dispatched to a residential fire Southeast Baltimore. First arriving companies observed a row house of ordinary construction with a large volume of smoke and flames issuing from the basement and extending to the first floor.

According to a department spokesperson, the first engine took a line through the front door to the rear kitchen area where crew had some trouble finding the basement stairs. Another engine company went to the rear with a line to the outside stairwell leading to the basement and was just starting down the stairs. The first truck vented some skylights on the roof as well as the front basement windows. As crews were attempting to access the fire, some type of transient extreme fire behavior resulted in flames blowing through the unit and out the front door, rear stairwell, second floor windows, and skylights. The firefighter from the first arriving truck assigned to the roof described the sound of a freight train coming through.

Five firefighters injured as a result of this explosive fire behavior phenomenon were transported to area hospitals. The officer of the first in engine company was admitted to the Bayview Burn Center, where he is listed in stable condition


Find more videos like this on firevideo.net

What Happened?

As always when a video of an incident involving extreme fire behavior is posted to the web, there is ongoing debate about what happened. Was it a backdraft? Was it a flashover? An interesting debate, but the value is not so much in being “right”, but in understanding how these phenomena occur, what might have happened in this incident, key indicators that may (or may not) be visible in the video, and most importantly how to prevent this from happening to us and the firefighters that we work with!

Flashover: sudden transition to fully developed fire. This phenomenon involves a rapid transition to a state of total surface involvement of all combustible material within the compartment.

Given adequate fuel and ventilation, a compartment fire may reach flashover as it develops from the growth to fully developed stage. However, when fire development is limited by the ventilation profile of the compartment, changes in ventilation will directly influence fire behavior.

For many years firefighters have been taught that ventilation reduces the potential for flashover. However, when a fire is ventilation controlled, heat release rate is limited by the available oxygen. Under these conditions; increasing air supply by creating opening results in increased heat release rate. This increased heat release rate may result in flashover.

If a fire is sufficiently ventilation controlled and a high concentration of excess pyrolizate and unburned flammable products of combustion accumulate in a compartment, the outcome of increased ventilation may be different.

Backdraft: Deflagration of unburned pyrolyzate and combustion products following introduction of air to a ventilation controlled compartment fire and ignition of the fuel/air mixture. This deflagration results in a rapid increase in pressure within the compartment and extension of flaming combustion through compartment openings. Occurrence of this phenomenon requires an atmosphere in which the fuel concentration is too high to deflagrate without introduction of additional oxygen.

As introduced in Extreme Fire Behavior: An Organizational Scheme, extreme fire behavior phenomena can be classified on the basis of outcome and conditions (see Figure 1)

Figure 1. Extreme Fire Behavior Classification.

extreme_fire_behavior_sr

Use of this approach may aid in making sense of what may have occurred in the Baltimore incident. But, it is often difficult to classify extreme fire behavior phenomena into discrete, black and white categories. What is the dividing line between a ventilation induced flashover and a backdraft. One key difference may be the speed with which heat release rate increases, but where is the dividing line (see Figure 2)?

Figure 2. The Gray Area.

gray_area

Keep in mind that while being right is great, it is more important to work through the process of figuring things out to improve your understanding.

Near Miss in Gary

Monday morning January 18, 2010 firefighters in Gary, Indiana were operating at a residential fire at 24th and Massachusetts when they experienced a near miss involving rapid fire progression. Have a look at video of this incident and give some thought to what influenced fire behavior. Also look at the similarities and differences between the extreme fire behavior that occurred in the Baltimore and Gary incidents.

Master Your Craft

Back on Task!

I have been extremely busy working on a project for the National Institute for Occupational Safety and Health and preparing for the International Fire & Rescue Congress in Valdivia, Chile. Next week’s post will provide a quick update on training conducted at the Congress.

After returning from Chile, I will be back on task with examination of the concept of battle drills to develop effective reaction to worsening fire conditions while operating in an offensive mode.

Ed Hartin, MS, EFO, MIFireE, CFO

Reading the Fire 13

Thursday, January 7th, 2010

As we start the New Year it is a good time to reaffirm our commitment to mastering our craft. Developing and maintaining proficiency in reading the Fire using the B-SAHF (Building, Smoke, Air Track, Heat, and Flame) organizing scheme for fire behavior indicators, requires practice. This post provides an opportunity to exercise your skills using a video segment shot during a residential fire.

Residential Fire

Early on the morning of December 23, 2009, the Cheektowaga Police department was dispatched to 305 Highland Drive in Cheektowaga to investigate a 911 call for an unknown type problem. The female caller was screaming, but the dispatcher was unable to determine the nature of the emergency. The first arriving police unit discovered a residential fire with persons trapped, and requested fire response. The police officers rescued a male victim from just inside the door, but fire and smoke conditions prevented them from assisting the other occupants.

The Hy-View Volunteer Fire Company responded with a first alarm assignment and observed flames showing on Side C.

Download and the B-SAHF Worksheet.

Watch the first 1 minute 10 seconds (1:10) of the video. This segment was shot from Side B at the B/C Corner.  First, describe what you observe in terms of the Building, Smoke, Air Track, Heat, and Flame Indicators; then answer the following five standard questions?

  1. What additional information would you like to have? How could you obtain it?
  2. What stage(s) of development is the fire likely to be in (incipient, growth, fully developed, or decay)?
  3. What burning regime is the fire in (fuel controlled or ventilation controlled)?
  4. What conditions would you expect to find inside this building? If presented with persons reported (as the first arriving companies were) how would you assess potential for victim survival?
  5. How would you expect the fire to develop over the next two to three minutes

Now watch the remainder of the video clip and answer the following questions:

  1. Did fire conditions progress as you anticipated?
  2. A voice heard in the video states that this was a backdraft. Do you agree? Why or why not?

Hy-View Volunteer Fire Company personnel recovered two female civilian victims from the residents. However, all three victims died as a result of smoke inhalation.

Master Your Craft

Ed Hartin, MS, EFO, MIFIreE, CFO

Reading the Fire 12

Wednesday, December 2nd, 2009

As discussed in prior Reading the Fire posts and the ongoing series examining fire behavior indicators (FBI), using the B-SAHF (Building, Smoke, Air Track, Heat, and Flame) organizing scheme, developing proficiency requires practice. This post provides an opportunity to exercise your skills using three video segments shot during an apartment fire.

Apartment Fire

At 2235 hours on November 19th the Bethlehem, PA fire department dispatched Engines 6, 9, 7, Ladder 2 & Chief 205 for an apartment fire with persons reported at 1992 Gatewood Lane. On arrival Engine 6 reported a working fire in an end-of-row unit. Tower Ladder (TL) 2 made two vertical ventilation (exhaust( openings in the roof above the fire. Chief 205 requested a second and then third alarm as the fire extended rapidly into the trussloft.

Download and the B-SAHF Worksheet.

The video segment was shot after TL 2 opened the roof.  First, describe what you observe in terms of the Building, Smoke, Air Track, Heat, and Flame Indicators; then answer the following five standard questions?

  1. What additional information would you like to have? How could you obtain it?
  2. What stage(s) of development is the fire likely to be in (incipient, growth, fully developed, or decay)?
  3. What burning regime is the fire in (fuel controlled or ventilation controlled)?
  4. What conditions would you expect to find inside this building (on floor 2 and in the attic)?
  5. How would you expect the fire to develop over the next two to three minutes

Crews use a combination of exterior attack (from the tower ladder and the roof) and interior attack from the second floor to control the fire.

  1. Did fire conditions progress as you anticipated?
  2. What concerns would you have about working on the top floor or roof in the involved area?
  3. How did vertical ventilation influence the fire in the trussloft (think about positives and negatives)?
  4. What alternatives to vertical ventilation of this lightweight roof system could be used to control the fire and prevent extension over uninvolved units?

While this incident had a positive outcome, it is important to recognize the potential for collapse of lightweight, engineered structural systems such as truss roof assemblies. Tactical success in one incident is not necessarily a predictor of future success should conditions be different (e.g., duration of fire impingement on structural members prior to arrival, burning regime, changes to the ventilation profile, etc.).

Master Your Craft

Remember the Past

Line of duty deaths involving extreme fire behavior has a significant impact on the family of the firefighter or firefighters involved as well as their department. Department investigative reports and NIOSH Death in the Line of Duty reports point out lessons learned from these tragic events. However, as time passes, these events fade from the memory of those not intimately connected with the individuals involved. It is important that we remember the lessons of the past as we continue our study of fire behavior and work to improve firefighter safety and effectiveness on the fireground.

November 23, 2006
Firefighter Steven Mitchell Solomon
Atlanta Fire Department, Georgia

Firefighter Solomon was working a 24-hour shift on Thanksgiving Day. Shortly after 2000hrs, Atlanta Fire-Rescue dispatched a full first-alarm assignment for a reported fire in an abandoned house. On arrival, companies encountered heavy smoke showing from a boarded-up single-story brick structure. As other crews removed plywood window coverings and forced entry through the front door, the crew of Engine 16 prepared to advance a 1-3/4inch attack line into the house. Firefighter Solomon was on the nozzle as the line was advanced inside. The attack team immediately encountered high temperature and zero-visibility conditions. Within seconds after they entered, the battalion chief arrived, assumed command, and ordered the companies to operate in a defensive strategy. Before the line could be backed out, the interior became enveloped in flames and the 3 firefighters from Engine 16 lost track of each other. Two of the firefighters managed to escape through the front door. Firefighters who were outside saw the silhouette of a firefighter, enveloped in flames, running past the front door and moving toward the rear of the house. The fire was quickly knocked down and crews made entry from both the front and rear to conduct a search. Firefighter Solomon was located almost immediately by a member who was using a thermal imaging camera and several firefighters quickly removed him from the dwelling. He was unconscious and critically burned. When he was found, Firefighter Solomon had removed his helmet, hood, and SCBA facepiece. One boot was also missing. Although he received immediate treatment from firefighter/paramedics on the scene and was transported within minutes to a level-one trauma center and regional burn unit, Firefighter Solomon died 6 days later without regaining consciousness.

Ed Hartin, MS, EFO, MIFIreE, CFO

Moving Day!

Monday, November 9th, 2009

This morning I begin the process of relocation to beautiful Whidbey Island, Washington. Later this week I begin my new job as Fire Chief with Central Whidbey Island Fire & Rescue.

Coupeville Harbor at Sunrise

coupeville_harbor

As I have been packing and preparing for my move all weekend, I have not had time to develop an in-depth Monday morning post. However, I did run across an interesting video clip a few weeks ago that ties in well with our ongoing effort to develop skill in reading the fire.

R-Fire

On March 27, 2009 the Emerson and Red Oak Fire Departments were dispatched for a residential fire at 901 Lowell Ave in Emerson, IA. First arriving companies observed a fire on Floor 1 and smoke throughout the structure.

The following video clip appears to have been shot early in incident operations as positive pressure ventilation is being implemented.

Download the B-SAHF Worksheet to use as a reminder while watching the video clip.

As you view the video clip, what do the fire behavior indicators (particularly smoke and air track) tell you about the stage of fire development, burning regime, and effectiveness of tactical operations?

Questions

In addition to your general observations of B-SAHF indicators while you watched the video the first time, consider the following questions:

  • Watch the video clip again and examine conditions at the inlet between 0:21 and 0:25. What does the presence of smoke (and particularly dark smoke) pushing from the inlet indicate?
  • Continue the video and examine conditions between 1:02 and 1:10. What do you observe at this point? What do smoke and air track conditions indicate now?
  • Continue on and examine conditions closely between 2:28 and 2:48. What does the variation in smoke and air track indicators at different points on the exterior of the structure tell you?

Back on Schedule!

I plan to be back on track with the next post in the series examining nozzle techniques on Thursday, November 12. I have been having an e-mail conversation BC Mike Walker of the Oklahoma City Fire Department regarding nozzle techniques and flashover. Mike is working on a research project regarding “right for reach and left for life”. Interestingly, when I received Mike’s first e-mail, I was in the process of outlining an upcoming blog post on the concept of “Battle Drills” to deal with or escape from conditions such as those resulting from unplanned changes in ventilation (window failure, wind, etc.).

Ed Hartin, MS, EFO, MIFireE, CFO

Decay Stage Fires:
Key Fire Behavior Indicators

Thursday, October 29th, 2009

As discussed in Flashover and Fully Developed Fires: Key Fire Behavior Indicators, providing additional oxygen to a ventilation controlled fire will result in a corresponding increase in heat release rate (HRR). This occurs because oxygen is required to release the chemical potential energy in fuel. The energy released per unit of mass of oxygen is remarkably consistent for both natural and synthetic organic (carbon containing) fuels.

Thornton’s Rule specifies that one kilogram (1 kg) of oxygen is required to release 13.1 mega joules (MJ) of energy. Multiplying 13.1 MJ/kg of oxygen by 21% (the concentration of oxygen in air) provides a value of 2.751 MJ/kg of air. The Society of Fire Protection Engineering (SFPE) Handbook of Fire Protection Engineering (SFPE, 2002) rounds this value to 3.0 MJ/kg of air. For a more detailed discussion of Thornton’s Rule and the relationship between fuel, oxygen, and energy release, see Fuel and Ventilation.

Decay Stage

A compartment fire may enter the decay stage as the available fuel is consumed or due to limited oxygen. As discussed in relation to flashover, a fuel package that does not contain sufficient energy or does not have a sufficient heat release rate to bring a compartment to flashover, will pass through each of the stages of fire development (but may not extend to other fuel packages). On a larger scale, without intervention an entire structure may reach full involvement and as fuel is consumed move into the decay stage. However, there is another, more problematic way for the fire to move into the decay stage. When the ventilation profile of the compartment or building does not provide sufficient oxygen, the fire may move into the decay stage. Heat release rate decreases as oxygen concentration drops. While temperature follows heat release rate, the temperature in decay stage fire may remain high for some time (particularly in well insulated, energy efficient buildings). This presents a significant threat as solid fuel packages continue to pyrolize and the involved compartment(s) may contain a high concentration of hot, pyrolized fuel, and flammable gaseous products of incomplete combustion.

Ventilation Controlled Fires

Under ventilation controlled conditions excess pyrolizate and flammable products of combustion present in smoke are a significant hazard to firefighters. Let’s go back to the fire triangle to examine the nature of this threat. While fuel, heat, and oxygen are present in proportion to support combustion where the fire is burning, the heat of the fire is pyrolyzing more fuel vapor than the fire can consume. In addition, incomplete combustion results in production of flammable gases such as carbon monoxide. The speed of fire development is limited by the availability of atmospheric oxygen provided by the current ventilation profile of the compartment or building.

In his presentation, Fire Dynamics for the Fire Service, Dan Madrzykowski of the National Institute of Standards and Technology (NIST) discussed the increased potential for ventilation controlled, decay stage fires in today’s modern, energy efficient structures. Dan presented the time temperature curve illustrated in Figure 1 to describe modern fire development and the potential influence of firefighting tactics.

Figure 1. Fire Development in the Modern Environment

modern_fire_development

Note: Adapted from National Institute of Standards and Technology (NIST) Fire Dynamics for the Fire Service, D. Madryzkowski.

The data in Figure 1 could be presented as HRR over time as well, but as HRR cannot be measured outside the lab, temperature is often used to describe fire development in full-scale tests. When the fire is burning in a ventilation controlled state, any increase in the supply of oxygen to the fire will result in an increase in heat release rate. Increase in ventilation may result from firefighters making entry into the building (the access point is a ventilation opening), tactical ventilation (performed by firefighters), or unplanned ventilation (e.g., failure of window glazing due to elevated temperature).

It is essential to recognize when the fire is, or may be ventilation controlled and the influence of planned and unplanned changes in ventilation profile. Most compartment fires that progress into the growth stage are ventilation controlled when the fire department arrives. A bi-directional air track (smoke out the top and air in the bottom) is often a significant indicator of a ventilation controlled fire, but what about before the door is open?

Figure 2. Assessment of Conditions at the Door

door_questions

As combustion becomes more incomplete, smoke production increases, color darkens, and optical density increases. However, these indicators may be subtle when observing fire conditions from the exterior. Assessment of conditions must continue after making entry. Smoke and air track indicators can be particularly useful in addressing the stage of fire development and burning regime when working inside. In addition, flames moving through the hot gas layer are a strong indicator of a ventilation controlled fire (as well as a threat to your safety which should be dealt with immediately).

Ventilation Induced Extreme Fire Behavior

When the fire is ventilation controlled, increased air supply to the fire will result in increased heat release rate and depending on conditions may result in extreme fire behavior such as flashover or backdraft. While both phenomena result from an increase in ventilation, vent induced flashover and backdraft are different phenomena. The conditions required for a ventilation induced flashover are 1) a compartment fire which has an insufficient HRR to reach flashover due to ventilation controlled combustion, and 2) insufficient concentration of excess pyrolizate and unburned products of incomplete combustion to result in a backdraft. While complex, the key determinant in the occurrence of a backdraft is likely to be the concentration of gas phase fuel within the compartment.

While these phenomena are different, both present a significant threat to firefighters. Rapid fire progress due to ventilation induced flashover or backdraft is not an instantaneous process. Depending on a number of variables such as the location of the fire, current level of involvement, temperature of the smoke (hot gas) layer, and extent of the increase in ventilation these rapid fire progress phenomenon may take some time to occur. However, when it does, fire development will be extremely rapid! Firefighters entering a compartment or building containing an under ventilated fire must be aware of and manage the hazards presented by the potential for rapid fire progress. Remember, many if not most fires that have progressed beyond the incipient stage before firefighters arrival are ventilation controlled and present the potential for rapid fire progress with increased ventilation (see Situational Awareness is Critical).

Figure 3 lists the fire behavior indicators related to ventilation controlled decay stage conditions and the potential for ventilation induced extreme fire behavior. It is important to note that there are not always clear distinctions in the visual indicators for vent induced flashover and backdraft.

Figure 3.  FBI: Decay Stage

decay_indicators

Be Wary

Decay stage indicators can sometimes be subtle and conditions may not look too bad (maybe like an incipient or early growth stage fire if you are not paying close attention and consider the possibilities).

It is often assumed (incorrectly) that ventilation induced extreme fire behavior (flashover or backdraft) will occur immediately after an increase in ventilation. Depending on fire conditions and building configuration there may be a significant time lag between ventilation and resulting changes in fire behavior. When ventilation controlled decay conditions are indicated (or suspected), firefighters should move cautiously and take action to change conditions inside the building or compartment (e.g., gas cooling, ventilation).

You have responded to a fire in a one-story single family dwelling of wood frame construction. A fire which started in a bedroom on the Alpha Bravo corner of the structure has gone from fully developed to the decay stage due to a lack of oxygen as building openings (doors and windows) remain closed and intact.

  • What conditions would you expect to see from the exterior of the structure?
  • What indicators may be visible from the front door as you make entry?

A fire in the decay stage (particularly when this is due to limited oxygen) still presents a significant threat as conditions can change rapidly.

  • If the door at your entry point remains fully open, how will this influence fire behavior (assuming no other ventilation has been performed)?
  • How would fire behavior be influenced if a window (or windows) in the fire compartment are opened along with the door at your entry point?
  • What indicators would you anticipate observing as you traveled through the living room to the hallway leading to the bedroom?
  • What conditions would you find in the hallway outside the fire compartment?

After making entry, consider if conditions are different than you anticipated?

  • Why might this be the case?
  • What differences in conditions would be cause for concern?

Late Breaking News

I have been selected to serve as Fire Chief with the Central Whidbey Island Fire District in Washington and anticipate starting in my new position by mid November.

Over the next year I will also be serving on an advisory panel to assist Underwriters Laboratory with a research project on to examine the impact of ventilation on fire behavior in legacy and contemporary construction. Output from this project will include a formal technical report, articles in fire service publications, presentation to the fire service community, and a stand-alone web-based training module.

References

Society of Fire Protection Engineers (SFPE). (2002). The SFPE handbook of fire protection engineering (3rd ed.). Quincy, MA: National Fire Protection Association.

Madrzykowski, D. Fire dynamics for the fire service [PowerPoint Presentation], Gaithersburg, MD: National Institute of Standards and Technology.

Fully Developed Fires:
Key Fire Behavior Indicators

Thursday, October 22nd, 2009

This post continues examination of key indicators used to recognize stages of fire development (i.e., incipient, growth, fully developed, and decay), burning regimes (i.e., fuel and ventilation controlled) with a look at indicators of the fully developed stage of fire development. Most buildings are comprised of multiple, interconnected compartments and fire conditions can vary widely from compartment to compartment. Fire in the compartment of origin may have reached the fully developed stage, while adjacent compartments may have just entered the growth stage.

Figure 1. Fully Developed Fire

fully_developed_fire

National Institute for Occupational Safety and Health (NIOSH) Death in the Line of Duty Report F2007-02 (2009) recommends that fire service agencies: “Train fire fighters to recognize the conditions that forewarn of a flashover/flameover [rollover] and communicate fire conditions to the incident commander as soon as possible” (p. 2). Note: flameover and Rollover are synonyms.

Flameover (Rollover): The condition where unburned fuel (pyrolyzate) from the originating fire has accumulated in the ceiling layer to a sufficient concentration (i.e., at or above the lower flammable limit) that it ignites and burns; can occur without ignition of, or prior to, the ignition of other fuels separate from the origin. (NFPA 921, 2008, 3.3.67 and 3.3.137)

Recognition of key fire behavior indicators is critical. However, communication of this information to the incident commander (as it may impact on strategies) alone is not sufficient. Companies working in the fire environment must proactively mitigate this threat through effective fire control and ventilation strategies and tactics.

Flashover

Flashover is the sudden transition from a growth stage to fully developed fire. When flashover occurs, there is a rapid transition to a state of total surface involvement of all combustible material within the compartment. Conditions for flashover are defined in a variety of different ways. In general, ceiling temperature in the compartment must reach 500o-600o C (932o-1112o F) or the heat flux (a measure of heat transfer) to the floor of the compartment must reach 15-20 kW/m2 (1.32 Btu/s/ft2)-1.76 Btu/s/ft2). When flashover occurs, burning gases will push out openings in the compartment (such as a door leading to another room) at a substantial velocity (Karlsson & Quintiere, 2000).

It is important to remember that flashover does not always occur. There must be sufficient fuel and oxygen for the fire to reach flashover. If the initial object that is ignited does not contain sufficient energy (heat of combustion) and does not release it quickly enough (heat release rate), flashover will not occur (e.g., small trash can burning in the middle of a large room). Likewise, if the fire sufficiently depletes the available oxygen, heat release rate will drop and the fire in the compartment will not reach flashover (e.g., small room with sealed windows and the door closed). A fire that fails to reach a sufficient heat release rate for flashover to occur due to limited ventilation presents a significant hazard as increased ventilation may result in a ventilation induced flashover (see Understanding Flashover: Myths & Misconceptions Part 2 and The Ventilation Paradox).

Indicators of Flashover Potential

Recognizing flashover and understanding the mechanisms that cause this extreme fire behavior phenomenon is important. However, the ability to recognize key indicators and predict the probability of flashover is even more important. Indicators of potential or impending flashover are listed in Figure 2.

Figure 2. Indicators of Potential Flashover

flashover_indicators

If the fire in our residential scenario is nearing flashover (in the compartment of origin) what fire behavior indicators might be observed? Use the B-SAHF model to help you frame your answers.

You have responded to a fire in a one-story single family dwelling of wood frame construction. A fire which started in a bedroom on the Alpha Bravo corner of the structure is nearing flashover. A thick hot gas layer has developed in the bedroom and is flowing out the open door into the hallway. The fire has extended to the bed and flames in the plume have reached the ceiling and have begun to extend horizontally in the ceiling jet. Fuel packages below the level of the hot gas layer (e.g., furniture, carpet, and contents) are beginning to pyrolize.

  • What conditions would you expect to see from the exterior of the structure?
  • What indicators may be visible from the front door as you make entry?

Remember that fire conditions will vary throughout the building. While the fire is in the growth stage and nearing flashover in the bedroom, conditions may be different in other compartments within the building.

  • What indicators would you anticipate observing as you traveled through the living room to the hallway leading to the bedroom?
  • What conditions would you find in the hallway outside the fire compartment?
  • After making entry, consider if conditions are different than you anticipated?
  • Why might this be the case?
  • What differences in conditions would be cause for concern?
  • How might your answers to the preceding questions have differed if the bedroom door was closed and fire growth limited by ventilation?

Fully Developed Fire

At this post-flashover stage, energy release is at its greatest, but is generally limited by ventilation (more on this in a bit). Unburned gases accumulate at the ceiling level and frequently burn as they leave the compartment, resulting in flames showing from doors or windows. The average gas temperature within a compartment during a fully developed fire ranges from 700o-1200o C (1292o-2192o F)

Remember that the compartment where the fire started may reach the fully developed stage while other compartments have not yet become involved. Hot gases and flames extending from the involved compartment transfer heat to other fuel packages (e.g., contents, compartment linings, and structural materials) resulting in fire spread. Conditions can vary widely with a fully developed fire in one compartment, a growth stage fire in another, and an incipient fire in yet another. It is important to note that while a fire in an adjacent compartment may be incipient, conditions within the structure are immediately dangerous to life and health (IDLH).

Indicators of a Fully Developed Fire

Remember that a fully developed fire refers to conditions within a given compartment or compartments. It does not necessarily mean that the entire building is fully involved. Figure 3 lists indicators of fully developed fire conditions.

Figure 3. FBI-Fully Developed Stage

fully_developed_indicators

If the fire in our residential scenario has progressed to the fully developed stage (in the compartment of origin) what fire behavior indicators might be observed? Use the B-SAHF model to help you frame your answers.

You have responded to a fire in a one-story single family dwelling of wood frame construction. A fire which started in a bedroom on the Alpha Bravo corner of the structure has reached the fully developed stage and now involves the contents of the room and interior finish of this compartment.

  • What conditions would you expect to see from the exterior of the structure?
  • What indicators may be visible from the front door as you make entry?

Remember that fire conditions will vary throughout the building. While the fire is fully developed in the bedroom, conditions may be different in other compartments within the building.

  • What indicators would you anticipate observing as you traveled through the living room to the hallway leading to the bedroom?
  • What conditions would you find in the hallway outside the fire compartment?
  • After making entry, consider if conditions are different than you anticipated?
  • Why might this be the case?
  • What differences in conditions would be cause for concern?

Ventilation Controlled Fires

When the fire is burning in a ventilation controlled state, any increase in the supply of oxygen to the fire will result in an increase in heat release rate. Increase in ventilation may result from firefighters making entry into the building (the access point is a ventilation opening), tactical ventilation (performed by firefighters), or unplanned ventilation (e.g., failure of window glazing due to elevated temperature).

It is essential to recognize when the fire is, or may be ventilation controlled, and the influence of planned and unplanned changes in ventilation profile on fire behavior. Most compartment fires in the late growth stage or which are fully developed are ventilation controlled when the fire department arrives. Even if the fire has not entered the decay stage due to limited ventilation, the increased oxygen provided by increases in ventilation (such as that caused by opening the door to make entry) will increase heat release rate. This is not to say that increased ventilation is a bad thing, but firefighters should be prepared to deal with this change in fire behavior.

Master Your Craft

Remember the Past

Line of duty deaths involving extreme fire behavior has a significant impact on the family of the firefighter or firefighters involved as well as their department. Department investigative reports and NIOSH Death in the Line of Duty reports point out lessons learned from these tragic events. However, as time passes, these events fade from the memory of those not intimately connected with the individuals involved. It is important that we remember the lessons of the past as we continue our study of fire behavior and work to improve firefighter safety and effectiveness on the fireground.

October 29, 2008
Firefighter Adam Cody Renfroe
Crossville Fire Department, Alabama

The Crossville Fire Department was dispatched to a fire in a single-family residence. was on the first engine to arrive on the scene to find thick, black smoke from the roof and a report that all occupants were out of the house.

Firefighter Renfroe and another firefighter advanced a hoseline to the front door of the residence. He sent the other firefighter back to the fire truck for a tool. When the firefighter returned, Firefighter Renfroe was gone and the nozzle remained by the doorway. At about the same time, the fire inside of the structure intensified. Firefighter Renfroe transmitted a distress message from the interior. Firefighters were not immediately able to enter the structure due to fire conditions.

Firefighters discovered Firefighter Renfroe about 4 feet from the home’s back door, but By the time firefighters reached him, he was deceased. The cause of death was smoke inhalation and thermal burns.

For more information on this incident, see NIOSH Death in the Line of Duty Report F2008-34.

Ed Hartin, MS, EFO, MIFireE, CFO

References

Karlson, B. & Quintiere, J. (2000) Enclosure fire dynamics. Boca Raton, FL: CRC Press.

National Institute for Occupational Safety and Health (NIOSH). (2009). Death in the Line of Duty Report F2007-02. Retrieved October 22, 2009 from http://www.cdc.gov/niosh/fire/pdfs/face200702.pdf .