The last several weeks have brought a number of interesting things in the area of fire dynamics and firefighting operations. Before getting back to the question of Door Control Doctrine, take a few minutes to have a look at the ALIVE on-line interactive training program by the NYU Poly Fire Research Group and the recently released research report Study of the Effectiveness of Fire Service Vertical Ventilation and Suppression Tactics in Single Family Homes

ALIVE On-Line Interactive Training

NYU Poly Fire Research Group has teamed up with the FDNY, Chicago Fire Department (CFD) the Bloomington Fire Department (BFD), the Eagan Fire Department (EFD), and the Eden Prairie Fire Department (EPFD) to develop a web-based, interactive firefighter training program – ALIVE (Advanced Learning through Integrated Visual Environments).

nyu_poly_fire_research

A recently released training module addresses the implications of fire dynamics and lightweight/engineered construction on firefighting operations in residential occupancies. Narrated by FDNY Lieutenant John Ceriello, this training program provides an excellent integrated review of current research conducted by UL, NIST, FDNY & the CFD and its application to fireground operations. The on-line training is available for use on a PC as well as an iOS and Android app. Have a look and share this important training with others!

UL Vertical Ventilation

Underwriters Laboratories Fire Service Research Institute (UL FSRI) recently released the research report Study of the Effectiveness of Fire Service Vertical Ventilation and Suppression Tactics in Single Family Homes.

ul_vertical

In conjunction with with the previous study on horizontal ventilation, this report provides a solid look at the capabilities and limitations of tactical ventilation in a residential context. Download a copy of the report and review the tactical implications (or read the entire report if you are extremely ambitious). The outcomes of this research will be explored in detail in upcoming CFBT-US blog posts.

Visit the UL FSRI web site and Facebook Page for regular updates on UL’s ongoing research with the fire service!

Door Control Doctrine

Doctrine is a guide to action rather than a set of rigid rules. Clear and effective doctrine provides a common frame of reference, helps standardize operations, and improves readiness by establishing a common approach to tactics and tasks. Doctrine should link theory, history, experimentation, and practice to foster initiative and creative thinking.

Given what we know about the modern fire environment and the influence of both existing and increased ventilation on ventilation controlled fires, what guidance should we provide to firefighters regarding door control? The following questions are posed in the context of a residential occupancy (one or two-family home, garden apartment unit, townhouse, etc.).

door_entry_drill

If the door to the fire occupancy is open when the first company arrives, should it be (immediately) closed by the member performing the 360o reconnaissance? If so why? If not, why not?

In general, if the door is open it should be closed as soon as possible. In the modern fire environment, most fires beyond the incipient stage will be ventilation controlled when the first company arrives. Closing the door until the first line is ready to enter will limit air flow to the fire and reduce heat release rate.

If the door should be closed immediately there any circumstances under which it should not? If there are circumstances under which the door should not be closed, what are they and why?

If the fire is not ventilation controlled, closing the door will not have a positive impact. However, it is unlikely to have a negative effect as well. If occupants remain inside (or have gone back in through the open door in an effort to rescue others), an argument could be made that closing the door might make it more difficult for them to find the exit. However, under ventilation controlled conditions, the increased air supply will quickly make conditions untenable and the flow path between the open door and the fire will result in fire spread along this path, further reducing tenability and potential for safe occupant egress. The short answer is no. If the door is open, close it.

If the door is closed on arrival (or you closed the door during the 360o reconnaissance) when and how should it be opened for entry? Think about tactical size-up at the door, forcible entry requirements, and the actual process of opening the door and making entry? How might this differ based on conditions?

When the door is opened, the clock is ticking on increased heat release rate (HRR). The door should remain closed until a charged hoseline is in place and the crew on the hoseline is ready to make entry for fire attack.

The door entry procedure should include assessment of B-SAHF indicators and forcible entry requirements (if the door is closed and locked). If forcible entry is required, it may be forced before the crew is ready to enter, but should be controlled in a closed position after it is forced. The door may be opened briefly and partially to assess conditions and if necessary to cool the hot upper layer prior to entry, but should generally remain closed until the crew on the hoseline enters the building.

After making entry should the door be closed to the greatest extent possible (i.e., leaving room for the hoseline to pass)? If so why? If not, why not?

If the fire is shielded from direct attack from the door, it should be closed after entry to limit air flow to the fire and reduce the flow path between the entry point and the fire. Limiting air flow will slow the increase in HRR. Limiting the flow path (it cannot be eliminated by closing the door completely due to the space required to pass the hoseline) will reduce the risk of fire spread towards the entry point.

If the door should be closed to the greatest extent possible, who will maintain door control and aid in advancement of the line? How might this be accomplished with limited staffing?

This is a significant question! As always, it depends. With a four person crew, one member may control the door with a two person team working inside. With smaller crew sizes, the standby team (two-out) may be able to control the door. If operating with limited staffing (three) in rescue mode, the apparatus operator may need to add door control to their rather substantial list of critical tasks after charging the attack and standby lines).

If you are performing search, should doors to the rooms being searched be closed while searching? If so why? If not, why not? Are there conditions which would influence this decision? If so, what are they?

In the past, firefighters may have been trained to “vent as you go” when searching. The concept was that venting the rooms being searched would improve tenability and increase visibility. However, horizontal ventilation also creates a flow path between the fire and the ventilation opening. If the opening serves as an inlet (due to vertical position in relation to the fire or wind effects), it may improve conditions in the room, but has the potential to worsen fire conditions due to increased HRR. If the opening serves as an outlet, a flow path for fire spread is created, which will potentially worsen conditions in the room being searched.

Closing the door to the room being searched allows the searcher to tactically ventilate the room if necessary while preventing a flow path between the fire and the room being searched.

Should the doors to rooms which have been searched be closed after completing the primary search? If so why? If not, why not? Are there conditions which would influence this decision? If so, what are they?

As with closing the door, it depends. Tactical ventilation must be planned, systematic, and coordinated. If the fire is being controlled (water on the fire) and the location of the opening in the compartment which has been searched is advantageous and part of the ventilation plan, leaving the door open is necessary. If the location is not advantageous and part of the plan, it should be closed.

How else can doors be used to aid in fire control or the protection of occupants and firefighters? Give this some thought!

As seen in the UL horizontal and vertical ventilation research projects, a closed door provides an area of refuge for both building occupants and if necessary for firefighters. Be mindful of potential areas of refuge while working inside, particularly if you are not on a hoseline, or in the event that water supply in your hoseline is compromised.

LA County Fire Department adopts door control doctrine! In a recent video posted on the LA County Fire Department Training Division web site, Battalion Chief Derek Alkonis explains the department’s door control doctrine and how this integrates into residential fire attack with three and four person engine companies. While the use of straight streams in an effort to cool hot gases overhead differs considerably than the use of pulsed water fog advocated by CFBT-US, this video provides an excellent example of effective door control and integration of tactical anti-ventilation, fire control, and tactical ventilation.

UL Ventilation Course

Saturday, December 18th, 2010

Impact of Ventilation on Fire Behavior

Earlier this year, Underwriters Laboratories (UL) conducted a series of full-scale experiments to determine the influence of ventilation on fire behavior in legacy and contemporary residential construction (see Did You Ever Wonder?).

UL University recently releases an on-line training program based on this research. Impact of Ventilation on Fire Behavior in Legacy and Contemporary Residential Construction is an excellent examination of the influence of ventilation on fire behavior and discussion of the tactical implications of the lessons learned through this research.

Every Firefighter and Fire Officer should complete
this training program within the next 30 days!

Completion of this on-line program could be the most important 90 minutes of training that you complete in the next year! I do not make this statement lightly. Understanding the relationship between ventilation and fire behavior is a critical competency for firefighters and fire officers.

After completing this on-line training program, consider the following questions and discuss them with the firefighters and fire officers you work with:

  • What are the indicators of a ventilation controlled fire?
  • How do your forcible entry and door entry procedures influence fire behavior?
  • How do you (or do you) coordinate fire attack and ventilation? How can tactical coordination be improved in your department?
  • What hazards are presented when performing VES (Vent, Enter, & Search) under ventilation controlled conditions? How can these hazards be mitigated?
  • What influence do closed doors have on the survivability profile (for either civilian occupants or trapped firefighters)?
  • What other lessons can you draw from this important research?

Research Report

In addition to the on-line course, UL has published a comprehensive report on this important research projects: Impact of Ventilation on Fire Behavior in Legacy and Contemporary Residential Construction.

Video

You can also download an excellent video illustrating the difference between fuel characteristics and loading in legacy and contemporary residential occupancies. This video is a tremendous tool to illustrate changes in the built environment to both firefighters and civilian audiences.

High Resolution Video

Low Resolution Video

Lima Backdraft

I am still working the report on my staff ride to the site of the 1997 backdraft at Luis Giribaldi Street and 28 de Julio Street in the Victoria section of Lima, Peru and should have it posted within the next week.

Ed Hartin, MS, EFO, MIFireE, CFO

Did You Ever Wonder?

Thursday, December 24th, 2009

The ability to read the fire and predict likely fire behavior is a critical skill for both firefighters and fire officers. Previous posts have examined how to use the B-SAHF scheme to recognize critical fire behavior indicators and identify the stage of fire development, burning regime, and potential for extreme fire behavior such as flashover or backdraft. However, there is something missing!

Experience is critical to adapting standard procedures and practices to a complex and dynamic operational environment. However, learning about fire behavior and changes in fire conditions based on fireground observations are a bit like a black box test. Black box testing is a technique for testing computer software in which the internal workings of the item being tested are not known by the tester. This is not entirely true in the case of fire behavior, but there is much that we dont know when assessing conditions on the fireground. How long has the fire been burning? What are the specific characteristics of the fuel? What sort of internal compartmentation is present? What exactly is the ventilation profile? Some of these factors can be determined during fire investigation and it is also possible to determine (with some degree of uncertainty) what influence these factors had on the outcome of the incident. Did you ever wonder how fire behavior would have changed if you had used different tactics? Unfortunately, in real life there are no do overs!

UL Tactical Ventilation Research Project

One of the people who has asked himself the question of what would have changed if different tactics were used is Underwriters Laboratories Fire Protection Engineer Steve Kerber.

Underwriters Laboratories (UL) has received a Firefighter Safety Research and Development Grant from the Department of Homeland Security (DHS). This research project will investigate and analyze the impact of natural horizontal ventilation on fire development and conditions in legacy (older, more highly compartmented) and contemporary (multi-level, open floor plan) residential structures.

Preliminary work has included review of literature related to horizontal ventilation and incidents in which ventilation had a significant influence on firefighter injuries and fatalities. In addition, UL has done preliminary work on the performance of various structural components such as single and multi-pane windows as preliminary input for design of full scale residential fire experiments.

In mid-December 2009, Steve Kerber met with the project advisory panel comprised of Captain Charles Bailey, Montgomery County (MD) Fire Department; Lieutenant John Ceriello New York City Fire Department, Firefighter James Dalton and Director of Training Richard Edgeworth, Chicago Fire Department, Chief Ed Hartin, Central Whidbey Island (WA) Fire & Rescue, Chief Otto Huber Loveland-Symmes (OH) Fire Department, and Chief Mark Nolan, Northbrook (IL) Fire Department. In addition, the advisory panel includes Fire Protection Engineers Dan Madrzykowski from the National Institute of Standards and Technology (NIST) and Dr. Stefan Svensson, a research and development engineer from the Swedish Civil Contingencies Agency.

Figure 1. Defining Experiment Parameters for the Contemporary Structure

kerber_plans

The main task presented to the advisory panel at the first meeting was to aid in defining the parameters for the experiment; including fire location, changes in ventilation profile, timing of these changes, and instrumentation to measure effects on fire development and conditions.

UL Large Fire Research Facility

The ventilation experiments will be conducted at the UL Large Fire Research Facility in Northbrook, IL. From the exterior, this facility simply looks like a large industrial building (see Figure 2). However, the interior of the structure includes a unique facility for fire research.

Figure 2. UL Large Fire Research Facility

ul_large_fire_lab_outside

One of the facilities inside this building is a 100 x 120 (30.48 m x 36.58 m) with a ceiling height that is adjustable up to 50 (15.24 m) (see Figure 3). All of the smoke resulting from tests in this facility is exhausted through a system designed to oxidize unburned fuel and scrub hazardous products from the effluent prior to discharge to the atmosphere. Tests are monitored from a control room that overlooks the large burn room.

Figure 3. Large Burn Room

ul_large_fire_lab_inside

Over the next month, the two residential structures to be used for the ventilation experiments will be constructed inside the large burn room at the UL Large Fire Test Facility. After construction is complete, a series of 16 full scale fire experiments is planned to evaluate a range of different horizontal ventilation scenarios.

Research with the Fire Service

Steve Kerber has often stated that it is essential that scientists and engineers conduct research with, not for, the fire service. Engagement between researchers and firefighters on the street is essential in advancement of our profession. With this ventilation research project, Underwriters Laboratories is actively engaged in this process.

The outcome of this project will not simply be an academic paper (but there might be one or more of those as well). As part of the DHS grant, UL will be developing an on-line course to present the results of the experiments and their practical application on the fireground.

Happy Holidays,

Ed Hartin, MS, EFO, MIFireE, CFO